Technical & Financial Calculation Engines
French Drain Calculator
A French drain calculator designs a subsurface drain to move groundwater away from your foundation. Enter the trench length, width and depth, and it works out excavation volume, washed-stone tonnage after subtracting pipe displacement, and the geotextile fabric needed to keep silt from clogging the drain.
- Drain pipe holes must always face down.
- A 50-ft trench (12 by 18 in) needs about 3.9 tons of washed stone.
- Keep at least a 1% slope — 1 inch of fall per 8 feet.
- Without geotextile fabric, silt can clog a drain in 2 to 5 years.
Loading calculator…
Calculation Formula & Mathematical Engine
Theoretical equation governing this computation.
Gravel_{tons} = \frac{(L \times W \times D - V_{pipe}) \times 1.10}{27} \times 1.35Variable Definitions
Step-by-Step Calculation Example
50-Foot French Drain Trench (12" Wide × 18" Deep)
- 1Gross trench volume: 50 × 1.0 × 1.5 = 75 cu ft
- 2Pipe displacement: 50 × π × (4/24)² ≈ 4.36 cu ft
- 3Net gravel volume: 75 - 4.36 = 70.64 cu ft ÷ 27 × 1.10 = 2.88 cu yds
- 4Gravel weight: 2.88 × 1.35 = 3.89 tons of washed stone
- 5Fabric wrap perimeter: 1.0 + (2 × 1.5) + 1.0 overlap = 5.0 ft width × 50 ft length = 250 sq ft
How to Install a French Drain
Follow these steps to get your result.
- 1Plan the drain route downhill to a safe outlet, allowing at least a 1% fall.
- 2Enter the trench length, width and depth to get the gravel tonnage and fabric area.
- 3Dig the trench — 12 inches wide and 18 inches deep is typical — and line it with non-woven geotextile fabric.
- 4Lay perforated pipe with the holes facing down, then backfill with washed #57 stone.
- 5Fold the fabric over the top like a burrito wrap and cover with soil or turf.
Comprehensive Practical Guide
In-depth analysis, domain guidelines, standard practices, and common pitfalls.
Why Non-Woven Geotextile Fabric Is Vital for Drainage
Without non-woven geotextile filter fabric surrounding the gravel trench ("burrito wrap"), fine silt and clay soil migrate into the stone voids, completely clogging the drain within 2 to 5 years.
How Much Slope Does a French Drain Need?
A French drain needs at least a 1% fall — 1 inch of drop per 8 feet of run — so water flows to the outlet instead of sitting in the pipe. On a 50 ft run that is about 6 inches of fall from start to finish. Discharge to daylight downhill, a dry well, or a storm drain where local rules allow — never onto a neighbour's land.
Frequently Asked Questions About French Drain Calculator
Direct, verified answers to common calculation and methodology questions.
Related Calculators
Explore complementary tools and related mathematical engines.
Paver and Paver Base Calculator
Calculate brick or concrete paver unit counts, crushed road base aggregate depth (4-8 inches), and bedding sand tonnage.
Retaining Wall Calculator
Calculate concrete retaining wall blocks, buried base embedment courses, and 12-inch drainage gravel backfill tonnage.
Gravel Calculator
Calculate gravel volume in cubic yards and weight in tons for crushed stone, pea gravel, and road base aggregates.